Kodak Ektalite 500 Service Manual page 42

Hide thumbs Also See for Ektalite 500:
Table of Contents

Advertisement

SERVICE MANUAL
23JUL01
4
Check the alignment of the INDEXER LEVER with the hole in the TOP PLATE
SM5766-1
ASSEMBLY at Position 1.
Page
42 of 96
5
Bend the INDEXER LEVER to the correct position.
6
Check the travel of the INDEXER LEVER in the FORWARD position. When the
INDEXER LEVER moves in the FORWARD position, the gate edge of the black plastic
should be between the 2 holes at Position 2.
7
Bend the INDEXER LEVER until you reach the correct position.
MECHANISM
ASSEMBLY
MECHANISM
RUNNING FIXTURE
TOP PLATE
Bend
here.
position 1
position 2
Adjustments
A091_0008HCA