Chapter 2 Installation and Wiring
(4) Recommended cable gauges, wiring accessories, and crimp terminals
Note: For compliance with CE and UL standards, see the safety precautions concerning EMC and the
compliance with UL and cUL standards under Safety Instructions.
The table below lists the specifications of cables, crimp terminals, and terminal screw tightening torques for
reference.
Motor
Applicable inverter
output
model
(kW)
11
L700-110LFF
15
L700-150LFF
18.5
L700-185LFF
22
L700-220LFF
30
L700-300LFF
37
L700-370LFF
45
L700-450LFF
55
L700-550LFF
75
L700-750LFF
11
L700-110HFF
15
L700-150HFF
18.5
L700-185HFF
22
L700-220HFF
30
L700-300HFF
37
L700-370HFF
45
L700-450HFF
55
L700-550HFF
75
L700-750HFF
90
L700-900HFF
110
L700-1100HFF
132
L700-1320HFF
160
L700-1600HFF
Note: Cable gauges indicate those of HIV cables (maximum heat resistance: 75°C).
*1)Please use the round type crimp terminals ( for the UL standard) suitable for the use electric wire when you
connect the electric wire with the main circuit terminal stand. Please put on pressure to the crimp terminals l with a
crimp tool that the terminal stand maker recommends.
(5) Connecting the control circuit to a power supply separately from the main circuit
If the protective circuit of the inverter operates to open the magnetic contactor in the input power
supply circuit, the inverter control circuit power is lost, and the alarm signal cannot be retained.
To retain the alarm signal, connect control circuit terminals R0 and T0 to a power supply.
In details, connect the control circuit power supply terminals R0 and T0 to the primary side of the
magnetic contactor as shown below.
(Connection method)
Power-receiving specifications
200 V class model:
200 to 240 V (+10%, -15%)
(50/60 Hz ±5%),(282 to 339 VDC)
400 V class model:
380 to 480 V (+10%, -15%)
(50/60 Hz ±5%),(537 to 678 VDC)
Gauge of power
2
line cable (mm
)
Grounding
(Terminals: R, S,
2
cable (mm
)
T, U, V, W, P, PD,
and N)
14
14
22
22
30
22
38
30
60 (22 2)
30
100 (38 2)
38
100 (38 2)
38
150 (60 2)
60
150 (60 2)
80
5.5
5.5
8
8
14
14
14
14
22
22
38
22
38
22
60
30
100(38X2)
38
100(38X2)
38
150(60X2)
60
80X2
80
100X2
80
External braking
Size of
resistor across
Crimp
terminal
terminals P and
terminal
screw
2
RB (mm
)
14
M5
R14-5
14
M6
22
M6
22
M6
30
M8
R60-8
M8
100-8
M8
100-8
M8
150-8
M10
R150-10 19.5(MAX22) RX400B (350A)
5.5
M5
R5.5-5
5.5
M6
R8-6
8
M6
R14-6
8
M6
R14-6
14
M6
R22-6
M6
M8
R38-8
M8
R60-8
M8
100-8
M10
R100-10 20.0(MAX22)
M10
R150-10 20.0(MAX35)
M10
80-10
M10
R100-10 20.0(MAX35)
J51
2 - 18
Applicable device
Tightening
torque (N-m)
Earth-leakage
breaker (ELB)
2.4(MAX4.0)
RX100 (75A)
22-6
4.0(MAX4.4)
RX100 (100A)
38-6
4.5(MAX4.9)
RX100 (100A)
38-6
RX225B (150A)
4.5(MAX4.9)
8.1(MAX8.8)
RX225B (200A)
8.1(MAX8.8)
RX225B (225A)
8.1(MAX20)
RX225B (225A)
8.1(MAX20)
RX400B (350A)
EX50C (30A)
2.4(MAX4.0)
4.0(MAX4.4)
EX60B (60A)
4.5(MAX4.9)
EX60B (60A)
RX100 (75A)
4.5(MAX4.9)
4.5(MAX4.9)
RX100 (100A)
38-6
4.5(MAX4.9)
RX100 (100A)
8.1(MAX20)
RX225B (150A)
8.1(MAX20)
RX255B (175A)
8.1(MAX20)
RX225B(225A)
RX225B(225A)
RX400B(350A)
20.0(MAX35)
RX400B(350A)
RX400B(350A)
Remove the connected cables.
Remove the J51 connector.
Connect the control circuit power
supply cables to the control
circuit power supply terminal
block.
Magnetic
contactor
(MC)
HK50
H65
H80
H100
H125
H150
H200
H250
H300
HK35
HK35
HK50
HK50
H65
H80
H100
H125
H150
H200
H250
H300
H400