Chapter 8 List of Data Settings
Code
Function name
C111
Overload setting (2)
C121
[O] input zero calibration
C122
[OI] input zero calibration
C123
[O2] input zero calibration
C130
Output 11 on-delay time
C131
Output 11 off-delay time
C132
Output 12 on-delay time
C133
Output 12 off-delay time
C134
Output 13 on-delay time
C135
Output 13 off-delay time
C136
Output 14 on-delay time
C137
Output 14 off-delay time
C138
Output 15 on-delay time
C139
Output 15 off-delay time
C140
Output RY on-delay time
C141
Output RY off-delay time
C142
Logical output signal 1 selection 1
C143
Logical output signal 1 selection 2
Logical output signal 1 operator
C144
selection
C145
Logical output signal 2 selection 1
C146
Logical output signal 2 selection 2
Logical output signal 2 operator
C147
selection
C148
Logical output signal 3 selection 1
C149
Logical output signal 3 selection 2
Logical output signal 3 operator
C150
selection
C151
Logical output signal 4 selection 1
C152
Logical output signal 4 selection 2
Logical output signal 4 operator
C153
selection
C154
Logical output signal 5 selection 1
C155
Logical output signal 5 selection 2
Logical output signal 5 operator
C156
selection
C157
Logical output signal 6 selection 1
C158
Logical output signal 6 selection 2
Logical output signal 6 operator
C159
selection
C160
Input terminal response time setting 1
C161
Input terminal response time setting 2
C162
Input terminal response time setting 3
C163
Input terminal response time setting 4
C164
Input terminal response time setting 5
C165
Input terminal response time setting 6
C166
Input terminal response time setting 7
C167
Input terminal response time setting 8
Input terminal response time setting
C168
FW
Multistage speed/position
C169
determination time
(Note)<>indicate the setting range of 90 to 160kW
Monitored data or setting
0.0 to 1.50 x "rated current" (A)
<0.0 to 1.50 x "rated current" (A)>
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
10ms)
8 - 12
Setting
Change
Default
during
during
operation
operation
Page
(allowed
(allowed
_FF
or not)
or not)
Rated
current
4-40
of
inverter
Factory
setting
Factory
setting
Factory
setting
0.0
0.0
0.0
0.0
0.0
0.0
4-75
0.0
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
00
00
00
00
4-69
00
00
00
00
00
00
00
00
00
1
1
1
1
1
4-75
1
1
1
1
0
4-48
-