Hitachi L700 SERIES Instruction Manual page 206

L700 series
Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Chapter 4 Explanation of Functions
(vi) List of registers (2nd control settings)
Register
Function name
No.
2103h
Acceleration (1) time setting, 2nd
motor
2104h
2105h
Deceleration time, 2nd motor
2106h
2107h to
(Reserved)
2202h
(vii) List of registers (function modes for the 2nd control settings)
Register
Function name
No.
Base frequency setting, 2nd
2203h
motor
Maximum frequency setting,
2204h
2nd motor
2205h to
(Reserved)
2215h
2216h
Multispeed frequency setting,
2nd motor
2217h
2218h to
(Reserved)
223Ah
Torque boost method selection,
223Bh
2nd motor
Manual torque boost value,
223Ch
2nd motor
Manual torque boost frequency
223Dh
adjustment, 2nd motor
V/F characteristic curve
223Eh
selection, 2nd motor
223Fh
(Reserved)
Voltage compensation gain
2240h
setting for automatic torque
boost, 2nd motor
Slippage compensation gain
2241h
setting for automatic torque
boost, 2nd motor
2242h to
(Reserved)
224Eh
224Fh
Frequency upper limit setting,
2nd motor
2250h
2251h
Frequency lower limit setting,
2252h
2nd motor
2253h to
(Reserved)
226Eh
226Fh
Acceleration (2) time setting,
2270h
2nd motor
2271h
Deceleration (2) time setting,
2nd motor
2272h
Select method to switch to
2273h
Acc2/Dec2, 2nd motor
2274h
Acc1 to Acc2 frequency
transition point, 2nd motor
2275h
2276h
Dec1 to Dec2 frequency
2277h
transition point, 2nd motor
2278h to
(Reserved)
230Bh
Function code
R/W
Monitoring and setting items Data resolution
F202 (high)
R/W
1 to 360000
F202 (low)
R/W
F203 (high)
R/W
1 to 360000
F203 (low)
R/W
-
-
Inaccessible
Function
R/W
Monitoring and setting items Data resolution
code
A203
R/W
30 to "maximum frequency, 2nd motor"
A204
R/W
30 to 400
-
-
Inaccessible
A220 (high)
R/W
0 or "start frequency" to "maximum frequency,
2nd motor"
A220 (low)
R/W
-
-
Inaccessible
0 (manual torque boost), 1 (automatic torque
A241
R/W
boost)
A242
R/W
0 to 200
A243
R/W
0 to 500
0 (VC), 1 (VP), 2 (free V/f), 3 (sensorless vector
A244
R/W
control), 4 (0Hz-range sensorless vector)
-
-
Inaccessible
A246
R/W
0 to 255
A247
R/W
0 to 255
-
-
Inaccessible
A261 (high)
R/W
00 or "2nd minimum frequency limit" to
"maximum frequency, 2nd motor"
A261 (low)
R/W
A262 (high)
R/W
00 or "start frequency" to "maximum frequency,
A262 (low)
R/W
2nd motor limit"
-
-
Inaccessible
A292 (high)
R/W
1 to 360000
A292 (low)
R/W
A293 (high)
R/W
1 to 360000
A293 (low)
R/W
0 (switching by 2CH terminal), 1 (switching by
A294
R/W
setting), 2 (switching only when the rotation is
reversed)
A295 (high)
R/W
0 to 40000
A295 (low)
R/W
A296 (high)
R/W
0 to 40000
A296 (low)
R/W
-
-
Inaccessible
4 - 144
Register
No.
0.01 [sec.]
0.01 [sec.]
-
Register
No.
1 [Hz]
1 [Hz]
-
0.01 [Hz]
-
-
0.1 [%]
0.1 [%]
-
-
1
1
-
0.01 [Hz]
0.01 [Hz]
-
0.01 [sec.]
0.01 [sec.]
-
0.01 [Hz]
0.01 [Hz]
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents