Fluke 5700A Series II Service Manual page 134

Multi-function calibrator
Hide thumbs Also See for 5700A Series II:
Table of Contents

Advertisement

5700A/5720A Series II Calibrator
Service Manual
Output
Level
2.1V
1.0V
0.3V
0.1V
30 mV
10 mV
3 mV
1 mV
Output
Frequency
Level
3V
1V
300 mV
100 mV
3-64
Table 3-31. Wideband Accuracy at 1 kHz Test Record
Measured
Spec
Error
ppm (90-day)
2238
2900
2833
3400
3333
3900
4833
5400
Table 3-32. Wideband Flatness Test Record
Measured
Flatness Error
10 Hz
30 Hz
10 kHz
120 kHz
500 kHz
2 MHz
5 MHz
10 MHz
20 MHz
30 MHz
10 kHz
120 kHz
500 kHz
2 MHz
5 MHz
10 MHz
20 MHz
30 MHz
10 kHz
120 kHz
500 kHz
2 MHz
5 MHz
10 MHz
20 MHz
30 MHz
10 kHz
120 kHz
500 kHz
2 MHz
5 MHz
10 MHz
20 MHz
30 MHz
5790A
1-Year Spec
ppm
24
24
38
53
115
240
643
1720
5790A
Spec
1-Year
ppm
Spec
(90-day)
3000
1000
1000
300
1000
300
1000
300
1000
300
1000
500
2000
1000
2000
1000
4000
1500
10000
3500
1000
300
1000
300
1000
300
1000
500
2000
1000
2000
1000
4000
1500
10000
3500
1000
300
1000
300
1000
300
1000
500
2000
1000
2000
1000
4000
1500
10000
3500
1000
400
1000
400
1030
400
1030
500
2030
1000
2030
1000
4030
1500
10030
3500
Test
TUR
GB
Limit
Factor
93
1.000
2238
121
1.000
2900
74.5
1.000
2833
64.1
1.000
3400
29.0
1.000
3333
16.2
1.000
3900
7.5
1.000
4833
3.14
0.980
5292
Test Limit
TUR
GB
ppm
Factor
3.00
0.980
2940
3.33
0.988
988
3.33
0.988
988
3.33
0.988
988
3.33
0.988
988
2.00
0.932
932
2.00
0.932
1864
2.00
0.932
1864
2.67
0.968
3872
2.86
0.975
9750
3.33
0.988
988
3.33
0.988
988
3.33
0.988
988
2.00
0.932
932
2.00
0.932
1864
2.00
0.932
1864
2.67
0.968
3872
2.86
0.975
9750
3.33
0.988
988
3.33
0.988
988
3.33
0.988
988
2.00
0.932
932
2.00
0.932
1864
2.00
0.932
1864
2.67
0.968
3872
2.86
0.975
9750
2.50
0.961
961
2.50
0.961
961
2.58
0.964
993
2.06
0.936
964
2.03
0.933
1894
2.03
0.933
1894
2.69
0.970
3909
2.87
0.976
9789

Hide quick links: