Download Print this page

Set Pool Operation - HP XP20000/XP24000 Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96085, may 2011)
Hide thumbs Also See for XP20000/XP24000:

Advertisement

Detailed Information
Detailed information displays for this operation, as shown in
Table 310 Pool SIM Comp Req Operation
Item
SIM
Num. of SIMs

Set Pool Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[VVOL], Set Pool,,Normal end,,,Seq.=xxxxx
+{Pool ID, Pool Type, Threshold(%), Pool Result}=[{ 1,2,20% , Normal end }]
Num of Pool = 1++{LDKC:CU:LDEV, LDEV Result} =[{0x00:0x00:0x00 , Normal end},
{0x00:0x00:0x01,Normal end},
{0x00:0x00:0x02,Normal end}] Num. of LDEVs = 3
[VVOL]
V Volume function
Set Pool
Set Pool operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 31 1 Set Pool Operation
Item
Pool ID
Pool Type
Threshold (%)
Pool Result
Num of Pool
LDKC:CU:LDEV
LDEV Result
Num. of LDEVs
250 VVOL Function
Description
The reference code of the Service Information Message (SIM) generated in the storage
system with resolved errors or service request status. No SIM reference code appears if
the SIM cannot be completed due to the unsatisfied requirements.
0xXXXXXX: Reference code of the SIM
The number of SIMs with resolved errors and service request status.
Description
The pool ID of the created pool.
The pool type. 1 is always output.
1: HP XP Snapshot, 2: HP XP Thin Provisioning Software
The threshold of the usage rate of the created pool.
The unit is percent (%).
The result of pool creation.
Normal end: Normal end, Error(xxxx-yyyy): Abnormal end, Not Execute: Not Executed
xxxx: Part code, yyyy: Error code
The number of the created pool.
The LDKC number, the CU number and the LDEV number of the pool volume.
The result of the pool volume creation.
Normal end: Normal end, Error(xxxx-yyyy): Abnormal end, Not Execute: Not Executed
xxxx: Part code, yyyy: Error code
The number of the created pool volume.
Table 310 (page
250).
Table 31 1 (page
250).