37 TC for Mainframe Function
Add CTG Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[TC],Add CTG,,Normal end,,,Seq.=xxxxxx
+{LDKC,CTG,Path,Offloading(min.),Inflow Control,Copy Pending(min.),RCU Ready(min.),
Timer Type}=
{0x00,0x00,Fibre,005,Enable,05,05,System}
[TC]
TrueCopy for Mainframe function (for IBM z/OS)
Add CTG
Add Consistency Group operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 255 Add CTG Operation
Item
LDKC
CTG
Path
Offloading (min.)
Inflow Control
Copy Pending (min.)
RCU Ready (min.)
Timer Type
Add Pair Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00, [TC],Add Pair,,Normal end,,,Seq.=xxxxxx
+{M-VOL(LDKC:CU:LDEV),R-VOL(LDEV),S/N,LDKC,SSID,ControllerID,Type, Initial Copy,
Fence Level,Copy Pace, Priority,Diff,CFW,DFW,TS, CTG, Error Level,Result}=
-{0x00:0x00:0x00,0xFF,99999,0x00,0x0004,4,Async,Entire,Never,15,032,Auto,
Only M-VOL,-,-,0x00,Group,Normal End},
(snip)
-(snip), Num.of Pairs=xx
[TC]
TrueCopy for Mainframe function (for IBM z/OS)
Add Pair
Add Pair operation
Normal end
208 TC for Mainframe Function
Description
The LDKC number.
The consistency group number of the consistency group (CT group) newly registered.
The channel type set.
Fibre: Fibre Channel
The value set to the offloading timer of the sidefile. The unit is minute.
Indicates whether the inflow control to the cache is enabled or disabled.
Enable: Setting is enabled, Disable: Setting is disabled
The setting value for Time Out (Copy Pending). The unit is minute. When Time Out (Copy
Pending) is set to 0 (zero), None is output.
The setting value for Time Out (RCU ready). The unit is minute. When Time Out (RCU
ready) is set to 0 (zero), None is output.
The timer type set.
System: System timer, Local: Local timer, None: No timer (system timer)
Table 255 (page
208).