INSTALLATION
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location (Refer to "Locating Your
Gas fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements
(Refer to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2) Assemble Top and Side Standoffs (Refer to
"Unit Assembly Prior to Installation).
3) Slide unit into place.
4) Install vent (Refer to "Venting Arrangement"
sections).
5) Make gas connections (Refer to "Gas Line
Installation section).
6) Make electrical connections to receptacle
supplied with unit (recommended).
7) Install 1 AA battery into DC spark box.
8) Test the pilot (Refer to "Pilot Adjustment"
section).
9) Test Gas Pressure (Refer to "Gas Pipe Pres-
sure Testing" section).
10) Install standard and optional features. Refer
to the following sections:
a)
Optional Accent Light Installation
b)
Glass Crystals/ Optional Ceramic
Stones
c)
Optional Firebox Base Pebbles
d)
Optional Refl ective Panels
e)
Faceplate
f)
Remote Control or Wall Thermostat
11) Wall Mounted ON/OFF Switch:
Use the toggle wall switch supplied with the
manual package. Use of a "decor" switch
causes higher resistance which is a problem
on gas fi replaces.
12) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and operation fully explained to
customer.
8
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 26,000 Btu/h
(NG), after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances are met as
outlined in the "Clearances" section.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on a
metal or wood panel extending the full width
and depth of the appliance.
4) The Direct Vent Gas Fireplace can be
installed as follows:
Model #
Position
A)
HZ42:
See Thru
B)
HZ42:
See Thru
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The HZ42 ST Direct Vent Gas Fireplace is
approved for alcove installations, which meet
the clearances listed on this page.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review
your plans before installation.
Note: For Exterior Vent Termination
Locations see section "Exterior Vent
Termination Locations."