HZ42ST Accent Light Assembly Kit # 586-959
1
910-814
4
910-997
4
940-363
1
Light Assembly
1
918-829
Plug Wiring
Amber Glass
Important: 120 Volt AC power is required for the optional light.
The receptacle box will be installed on the lower left corner of
the unit and will need to be wired by a qualifi ed electrician prior
to the optional light installation. The neutral (wider) slot of the
polarized receptacle should be at the top. A wall mounted switch
should be installed to turn the accent lighting on/off.
See wiring diagram in the instruction manual.
1) Shut off electrical supply.
If faceplate is installed - complete steps 2 & 3 below.
2) Remove faceplate by lifting up off glass door - see below.
Faceplate
3) Slide out bottom faceplate panel - see below.
4) Remove the glass door - see instructions in manual.
5) Remove the glass crystals/optional ceramic stones or pebbles- if
installed.
6) Remove inner panels if installed - see instructions in manual.
34

OPTIONAL LIGHT INSTALLATION

Plug wiring + gasket
Halogen Bulb
Amber Glass
Includes gaskets (x 4)
Instruction Sheet
Light Diffuser
Glass Door
7) Remove bottom cover
8) Loosen 2 screws securing burner - slide burner away from
the pilot and lift out.
9) Remove cover plate located in the centre of the fi rebox fl oor
by removing 4 screws. Discard the cover plate and gasket - keep the
screws.
X
10) Feed the plug wiring through the opening in the middle of the
fi rebox - secure light assembly mounting plate with 4 screws
(use screws from cover plate).
HZ42ST Regency Horizon
Bottom cover
Screws
X
X
X
TM
Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz42st-lpHorizon hz42st

Table of Contents