Rigid/Flex Pipe Venting Systems; Horizontal Or Vertical Terminations - Regency Horizon HZ42ST-NG Owners & Installation Manual

Table of Contents

Advertisement

INSTALLATION
The minimum components required for a basic
horizontal termination are:
1
Simpson Duravent Adaptor
1
Horizontal Termination Cap
1
45
o
Elbow
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap. For
siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used
with vinyl siding), measure to outside surface of wall
without siding and add 2 inches.
Flat Wall Installation
Wall Thickness
(inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 11-1/2"
9" - 14-1/2'
15" - 23-1/2"
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct, ICC Excel, MetaFab venting
and Security Secure Vent systems. Use of
these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the
Intertek WHI listing of components.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
American Metal Products Ameri Vent Direct Vent, ICC Excel, MetaFab, Security Secure Vent
of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
20

RIGID/FLEX PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

Horizontal
Termination Cap
Wall Thimble
Vent Length Required
(inches)
6"
9"
12"
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
TM
and FPI
Vinyl Siding
Standoff (Optional)
Pipe Length
Rigid Pipe Adapter
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
®
, Selkirk Direct-Temp. AstroCap
HZ42ST Regency Horizon
o
90 Elbow
Pipe
Length
o
45 Elbow
®
Direct Vent,
TM
is a proprietary trademark
TM
Gas Fireplace