INSTALLATION
Horizontal or Vertical Terminations
The minimum components required for a basic horizontal termination are:
1
Horizontal Termination Cap
1
90
o
Elbow
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure
to outside surface of wall without siding and add 2 inches.
Alternate
Horizontal Ter-
mination Caps
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
American Metal Products Ameri Vent Direct Vent, Security Secure Vent
Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
22

RIGID PIPE VENTING SYSTEMS

Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
TM
and FPI
Wall Thickness
(inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 1-1/2"
9" - 14-1/2"
15" - 23-1/2"
Wall Thickness
(inches)
3-1/4" - 6-3/4"
7-3/4" - 16-1/4"
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
Standoff (Optional)
Adj.Pipe Length
11" - 14-5/8"
o
90 Elbow
24" Pipe
Length
Rigid Pipe Adaptor
(Must be used with all Rigid Piping)
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
®
, Selkirk Direct-Temp. AstroCap
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
Flat Wall Installation
Vent Length Required
(inches)
6"
9"
12"
11" - 14-5/8" Adj. Pipe
17" - 24" Adj.
Corner Installation
Vent Length Required
(inches)
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
6" + 12"
9" + 9"
6" + 9"
Vinyl Siding
Horizontal
Termination
Wall Thimble
When using Rigid Vent other than
®
TM
is a proprietary trademark of FPI Fireplace
Cap
Direct Vent ,