Safety Label - Regency P36-NG4 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Hide thumbs Also See for Regency P36-NG4:
Table of Contents

Advertisement

SAFETY LABEL

SAFETY LABEL
This is a copy of the label that accompanies
each P36 Zero Clearance Direct Vent Gas
Fireplace. We have printed a copy of the
contents here for your review. The safety
label is located on the front inside base of
the unit, visible when the bottom louver
is open.
NOTE: FPI
units are constantly being
improved. Check the label on the unit and
if there is a difference, the label on the unit
is the correct one.
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
Tested to:
CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007
WN# 16444
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
NATURAL GAS: Model P36-NG4
5"
Minimum supply pressure
3.8"
Manifold pressure high
1.1"
Manifold pressure low
#37
DMS
Orifice size
15,500
Btu/h
Minimum input
30,000
Btu/h
Maximum input
0-4500
ft/pi
Altitude
PROPANE GAS: Model P36-LP4
Minimum supply pressure
12"
Manifold pressure High
11"
Manifold pressure Low
2.9"
30,000 Btu for altitude 0 - 2000 ft.
Maximum Input
30,000 Btu/h
Minimum Input
15,000 Btu/h
#52
Orifice size
0-2000 ft/pi
Altitude
Convertible to 25,000 Btu for altitude 2000 - 4500 ft. with Orifice part #: 904-345
Maximum Input
25,000 Btu/h
Minimum Input
12,600 Btu/h
#53
Orifice size
2000-4500 ft/pi
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United
States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual
for details.
Fan (Part # 432-917) Optional Bay Window (Part #510-930) Option: HeatWave Kit # 946-556
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces
normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
6
é
CANADA and U.S.A.
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le P36-NG4
WC/C.E.
(1.25kPa)
Pression d'allimentation minimum
WC/C.E.
(0.95kPa)
Pression à la tubulure d' chappement lev e
WC/C.E.
(0.27kPa)
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
(4.54 kW)
D bit
é
Calorifique
(8.79 kW)
D bit
é
Calorifique
(0-1372 m)
l'altitude
É
QUIP A L'UISINE POUR GAZ PROPANE
É
WC/C.E. (3.00 kPa)
Pression d'allimentation minimum
WC/C.E. (2.74 kPa)
Pression
à
la tubulure d' chappement lev e
WC/C.E. (0.72 kPa)
Pression
à
la tubulure d' chappement basse
D bit Calorifique maximum
é
(8.79 Kw/h)
D bit Calorifique minimum
é
(4.40 Kw/h)
Dimensions de l'orifice
DMS
(1.61mm)
L'altitude
(0-610m)
(7.33 Kw/h)
D bit Calorifique maximum
é
D bit Calorifique minimum
é
(3.69 Kw/h)
DMS
(1.51mm)
Dimensions de l'orifice
(610-1372m)
L'altitude
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
Duplicate S/N
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
é
é
é
é
é
minimum selon
maximum selon
B
é
é
é
é
The "Bay Louvers"
used with the Bay Glass option
DOOR SEAL: Please
check that the door is
(See Instruction Manual for
detailed instructions)
294
Serial No./ No de serie
294
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Ceiling
0" Clearance to
combustibles from:
Top, sides, bottom and rear of unit
32"
Mantel Clearances from Top:
A
(A) Min. 7" (177mm)
B
Side Wall Clearance
from Side Facing
B) 6" with Flush or Bay Front
B) 8" with Barcelona Trim
Alcove approved for
Bay & Flush Louvers.
Alcove Clearances:
Max. Depth 36" (914mm)
MUST
be
Min. Width 48" (1219mm),
Min. Height 72" (1229mm)
Minimum Vent Clearances:
Horizontal Top
Horizontal Side
Horizontal Bottom 1-1/2" (38mm)
properly sealed
Vertical Vent
FPI Fireplace Products International Ltd.Delta, BC, Canada
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
Made in Canada/
Fabrique au Canada
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
2" (51mm)
1-1/2" (38mm)
1-1/4" (32mm)
918-499a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36-lp4P36-ng4P36

Table of Contents