Fan Installation (Optional); Fan Removal - Regency P36-NG4 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Hide thumbs Also See for Regency P36-NG4:
Table of Contents

Advertisement

FAN INSTALLATION
(OPTIONAL)
120 Volt AC power is needed for the fan switch
and blower. The fan can be hard wired if desired.
The receptacle box should be installed on the
left hand side of the unit by a qualifi ed electri-
cian. The neutral (wider) slot of the polarized
receptacle should be at the top.
Unit must be grounded at all times. Do
not cut the ground terminal off under any
circumstances.
1) Shut the power off.
2) Remove the standard fl ush door and the
optional bay door, if installed. Open the
bottom louver door.
3) Loosen the 2 screws holding the Burner
ON/OFF switch and bracket to the bottom
louver and lift the assembly out.
4) Turn the fan base on its side (with the base
facing towards you) and then slide the fan
in towards the rear of the unit. Turn the fan
upright and slip it over the two mounting
studs. Take care not to damage the insula-
tion on the fan base. Ensure that the fan
blades do not rub against the valve tub-
ing. Diagram 1.
5) Connect fan ground cable to ground lug.
Refer to wiring diagram.
6) Slide the thermodisc/cover assembly into
the bracket clip on the underside of the
fi rebox. Check that no wire will touch the
hot surfaces. Diagram 2.
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
7) Attach the Fan control box to the Burner
ON/OFF control box.
Use the clip & hook on the side of the control
boxes to join them together.
8) Secure the two boxes together with one
screw.
9) Position the control box assembly on the
bottom louver and mark the position of the
slot on the right side bracket.
Hold control box assembly in place and
mark the position of the right side slot
10) Remove the control box
Diagram 1
11) Attach the two control boxes to the bottom
louver and tighten the 2 screws on the left
side and 1 screw on the right side.
Secure left side with 2 screws.
Diagram 2
Secure right side with one screw.
assembly and push the hold-
down clip onto the louver. Bend
the tab until it is at 90
o
to the
louver.
INSTALLATION
12) Secure the fan wires and power cord by
attaching one of the adhesive backed wire
holder clips (Part #910-199) onto the stove
base. Use the second clip to bundle up the
wires approximately 4" from the control box.
Ensure that there is no interference with the
wires when the louver is closed and that
no wire will touch the hot metal surfaces or
sharp edges.
13) Plug the fan power cord into the rear end of
the receptacle box to provide the maximum
clearance from the louvers.

FAN REMOVAL

1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life. Do
not lubricate them. Make sure you vacuum
the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a soft
brush nozzle.
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and
on again without a minimum of a 60
second wait.
47