Table 21 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKT0x) (continued)
Message ID
YKT006W CON RC=16
YKT007W CON RC=16
YKT008E CON RC=20
YKT012E CON RC=16
YKT021E CON RC=20
YKT022E CON RC=4
YKT023E CON RC=16
YKT024E CON
YKT025E CON RC=4
YKT026E CON
YKT032E CON RC=20
YKT098I CON RC=0
YKT099I CON RC=0
Table 22 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKT2x)
Message ID
YKT210E CON RC=8
YKT21 1E CON RC=12
96
Messages
Message Text
Couldn't delete name/token
Couldn't delete SVC entry
System task started without
START from TSO.
Name/token error
Invalid parameter
SVC routine is already inserted
Couldn't delete SVC routine
Couldn't copy load module
SVC routine is already deleted
SVC # is already used
The task is not APF-authorized.
SVC routine is deleted
SVC routine is inserted
Message Text
System task started without START
from TSO.
Failed to allocate space in CSA
Explanation and Recommended Actions
Name/Token deletion failed.
Contact technical support for assistance.
SVC number deletion failed in the SVCUPDTE macro.
Contact technical support for assistance.
The YKALCSVC command was executed in the TSO/E
environment.
Execute the YKALCSVC command using the START
command or a batch job.
An error occurred in the Name/Token service.
Contact technical support for assistance.
A value specified in the PARM parameter is invalid.
Check the specification of the PARM parameter.
The user SVC routine is already registered.
The user SVC routine deletion failed.
Contact technical support for assistance.
Copying of the load module failed. The program
abnormally terminates with user completion code 996.
Contact technical support for assistance.
The user SVC routine is not registered or is deleted.
The specified SVC number is already used. The program
abnormally terminates with user completion code 996.
Specify an unassigned SVC number in the PARM
parameter of the YKALCSVC command, or re-execute
without the PARM parameter.
The dataset name of the Business Continuity Manager
load library was not registered in SYS1.PARMLIB.
Alternately, the execution of the command failed because
authorized/unauthorized datasets co-existed while
concatenating DD statements in the load library, and
they were handled as unauthorized datasets.
The user SVC routine deletion succeeded.
The user SVC routine registration succeeded.
Explanation and Recommended Actions
The command was invoked from the TSO/E
environment. The program stops processing.
Invoke the command using the START command, or
as a batch JOB.
A GETMAIN error occurred in CSA. The program stops
processing.
Contact technical support for assistance.