Table 47 Details of Error Codes 20xx – 22xx
Error
Error Details
Code
An BC Z copy pair cannot be made
2060
or resynchronized. The reason might
be one of the following:
The BC Z copy pair status cannot
be changed because the P-VOL
has already been made into a
copy pair by using Cnt Ac-J Z.
An BC Z copy pair cannot be made.
2061
The reason might be one of the
following:
The S-VOL has already been made
into a copy pair by using Cnt Ac-J
Z
The S-VOL is a journal volume.
An BC Z copy pair cannot be
2067
resynchronized because the specified
volume is part of a Cnt Ac-S Z and
Cnt Ac-J Z common volume
configuration and neither the Cnt Ac-S
Z nor Cnt Ac-J Z copy pair are in the
suspend status.
A BC Z copy pair could not be made
2078
because the status of the P-VOL for
the specified BC Z copy pair does not
meet all of the following conditions:
The S-VOL is part of a delta resync
pair
The delta resync pair is in the
HOLD status
A Cnt Ac-J Z copy pair that is
linked with the delta resync pair is
in the suspend status
Type of Error
BC Z
Cnt Ac-S Z
TCA
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Cnt Ac-J Z
CMD
PATH
Details of Error Codes 189
Others