HP StorageWorks P9000 Manual page 183

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ41x) (continued)
Message ID
YKZ415E MSG SC=48
RC=48
YKZ416E MSG SC=36
#1
RC=36
YKZ417E MSG SC=48
RC=48
YKZ418E MSG SC=48
RC=48
Message Text
The device indicated by devn in the
disk configuration definition file is on
a storage system that differs from sn.
Copygroup SUPFnc does not support
CA Map (DIF UNIT).
This command is invalid for CA Copy
Groups linkaged with HyperSwap.
OPENMFUPDATE cannot use with
reverse-resync.
Explanation and Recommended Actions
function: X'23' or higher
The device defined in the disk configuration
definition file exists on a storage system that differs
from the storage system in the disk configuration
definition file. For this reason, a NG scan cannot
be executed.
Check the device address domain ID specified in
the disk configuration definition file or the Set
Defaults panel. For details about the NG scan, see
the HP StorageWorks P9000 for Business Continuity
Manager Software Reference Guide.
devn (hexadecimal number)
Device number defined in the
disk configuration definition file
sn
Serial number of the storage
system on which the device
indicated by devn actually exists
This storage system does not allow Cnt Ac-S Z data
differential-data management units to be specified.
#2
Use a device
that allows Cnt Ac-S Z data
differential-data management units to be specified.
Also, if scanning was not performed after the
storage system microcode was replaced, perform
another scan.
SUPFnc (hexadecimal number)
Value for the version of the
storage system support function
used in the copy group
(minimum)
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
Units of Cnt Ac-S Z data differential-data
management units can be specified on storage
systems with the following versions of the storage
system support function:
XP12000/XP10000 disk array
Version of the storage system support function:
X'11' or higher
XP24000/XP20000 disk array
Version of the storage system support function:
X'20' or higher
The command cannot be executed for Cnt Ac-S Z
copy groups with the HyperSwap attribute.
Execute the PPRC copy pair operation from TPC-R.
A resynchronization that reverses the copy direction
cannot be performed with the OPENMFUPDATE
parameter specified. (The OPENMFUPDATE
parameter is used to modify the Open/MF
Consistency attribute.)
List of Messages 183