HP StorageWorks P9000 Manual page 94

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 20 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKS2x) (continued)
Message ID
YKS270E MSG SC=44
RC=44
YKS285E MSG SC=48
RC=48
94
Messages
Message Text
Failed to operation
configuration file. (name
=dataset-name, dsstate)
file-name is too long for a
filename.
Explanation and Recommended Actions
Creation of the configuration file is stopped because an
error occurred during the creation of the configuration
file. See the information output in the message to review
the environment, and then create the configuration file
again. For details about what action to take, see the
message that was output and the HP StorageWorks
P9000 for Business Continuity Manager Software User's
Guide.
operation
The operation performed for the configuration file
CREATE
An error occurred during the creation of the
configuration file.
UPDATE
An error occurred during the update of the existing
configuration file.
dataset-name
Name of the configuration file to be
created
dsstate
Status of the configuration file
EXTENT=extent
The number of extents of the dataset
that is currently allocated
extent indicates the number of
extents that are allocated to the
dataset indicated by dataset-name.
DSORG=VSAM
The dataset format is VSAM. A
dataset whose format is VSAM
cannot be used as a configuration
file. Change the dataset format of
the configuration file into PS.
CANNOT GET DSSTATE, reason
code=nnnn
The dataset information cannot be
obtained, or the configuration file
is not assigned.
nnnn (decimal (base 10) number)
indicates a reason code
(maintenance information).
The file name identified by file-name is too long. The file
name must consist of 44 or fewer characters.