HP StorageWorks P9000 Manual page 85

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 15 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKN0x) (continued)
Message ID
Message Text
YKN010E TSO
REXX failure return code=nnnn
RC=40
starting with variable name
YKN050E MSG
Invalid Copy Group attribute
SC=48 RC=48
name
(attribute-value)
YKN099I TSO
YKRUN command return
code=nnnn, reason code=rrrr
Table 16 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKP0x)
Message ID
Message Text
YKP000T TSO RC=48
Supplied parameters invalid
YKP001E TSO RC=48
No message MSG() supplied
YKP001E MSG SC=48
No results STEM() supplied
RC=48
YKP002E MSG SC=48
Copy Group STEM(stem) does
RC=48
not include trailing "."
YKP002E TSO RC=48
Messages MSG(stem) does not
include trailing "."
YKP002E MSG SC=48
This command is only valid for
RC=48
TCA or CAJ Copy Groups
Explanation and Recommended Actions
Access to the REXX variable identified by name failed.
For details about the return code, see IKJCT441 in the TSO/E
Programming Services.
nnnn
Error code returned upon REXX access
The specified copy group attribute value is invalid for this
command.
Correct the value and then re-execute the command.
name
REXX variable name
attribute-value
REXX variable value
The YKRUN command terminated with the return code nnnn
and the reason code rrrr.
This message is always displayed to indicate the return code
and the reason code.
nnnn
Maximum among the severity codes
returned during command execution
Explanation and Recommended Actions
Invalid parameters are specified.
For details, see the reason code in the YKP099I message
that will appear after this message. For reason codes, see
IKJPARS in the TSO/E Programming Services.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the STEM parameter.
The last character of the STEM parameter is not a period.
stem
Stem name assigned to the STEM
parameter
The last character of the MSG parameter is not a period.
stem
Stem name assigned to the MSG parameter
The YKSTATS command was executed on a copy group that
is neither TCA nor Cnt Ac-J Z. This command works only on
TCA or Cnt Ac-J Z copy groups.
Check that the command can be executed on this copy group,
and then re-execute the command.
List of Messages