Fujitsu ServerView Event Manager User Manual page 31

Serverview operations manager v6.12
Table of Contents

Advertisement

Error
iRMC S2/S3 SEL
code
entry
07000A 'PSU XY': Power
supply critical
temperature
07000F 'PSU XY': Power
supply fan prefailure
0C0004 'CPU XY': CPU
internal error (IERR)
0C0021 'CPU XY':
Uncorrected CPU
Machine Check
Architecture (MCA)
error
0C0007 'CPU XY': CPU clock
automatically
throttled
0C0017 'CPU XY': CPU
failure predicted
0C000B 'CPU XY': CPU
disabled
Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap
ServerView Event Manager
iRMC S2/S3 SEL Entries and SC2 MIB Traps
Trap text
Temperature at
power supply 'PSU
XY' in cabinet XY of
server XY has
reached the critical
level.
Fan failure is
predicted at power
supply 'PSU XY' in
cabinet XY of server
XY.
Internal error (IERR)
occurred on CPU
'CPU XY' in cabinet
XY of server XY.
CPU speed at server
XY changed to XY
percent of its
maximum speed.
CPU failure is
predicted for CPU
'CPU XY' in cabinet
XY.
CPU 'CPU XY' in
cabinet XY of server
XY is disabled.
Trap
Trap name
no.
2037 sc2TrapPower
SupplyCritical
Temperature
2038 sc2TrapPower
SupplyFan
Failure
Prediction
2082 sc2TrapCpu
Ierr
2080 sc2TrapCpu
Speed
Changed
2081 sc2TrapCpu
Prefail
2083 sc2TrapCpu
Disabled
31