Trap overview
Trap name
sieScUserAuthentication
Failure
sniScCpuSpeedChanged 656 CPU speed has changed
sniScFanAdded
sniScFanRemoved
sniScPowerSupply
RedundancyLost
sniScRedundant
FanFailed
sniScRedundant
PowerSupplyFailed
sniScShutdown
Cancelled
sniScVoltageOk
sniScVoltageTooHigh
sniScVoltageTooLow
svCommunication
Established
svCommunicationFailure 610 Communication with the
tempCritical
tempOk
Table 40: ServerControl traps (SC.mib)
134
ID
Meaning
664 User authentication failure
is detected via PPP, FTP,
HTTP or telnet.
because of temperature
problems.
653 The indicated hot-plug fan
was inserted.
654 The indicated hot-plug fan
was removed.
671 Power supply redundancy
no longer available.
648 The indicated redundant
fan failed.
649 One redundant hot-replace
power supply failed.
655 A pending server shutdown
was canceled by the user.
650 Power supply voltage is
within normal range again.
652 Power supply voltage is too
high.
651 Power supply voltage is too
low.
636 Communication with the
server management
controller was established.
server management
controller was interrupted.
604 The temperature has
reached a critical level.
602 The temperature is within
normal range.
Error class
major
informational
informational
informational
minor
major
major
informational
informational
critical
critical
informational
critical
critical
informational
ServerView Event Manager