Fujitsu ServerView Event Manager User Manual page 125

Serverview operations manager v6.12
Table of Contents

Advertisement

Trap name
fanFailureTrap
fanInformationTrap
lunFailureTrap
lunInformationTrap
lunReconstructTrap
lunReducedTrap
Table 37: PXRE traps
ServerView Event Manager
ID
Meaning
5
The fan in the specified
location has failed. Replace
fan.
6
The fan in the specified
location was recovered.
16
The LUN has failed and is
off-line. Possible cause is
too many failed disk drives
that make up the LUN, the
OS can no longer
communicate with the LUN
for other reasons.
19
A LUN has become optimal
due to successful
completion of the
reconstruction process.
17
The LUN has started the
reconstruction process but
is available for normal use.
Possible causes are an
available disk drive was
created as a spare to be
inserted into the set, an
existing spare was
automatically added to the
set for reconstruction upon
failure of a member disk
device.
18
A LUN has become
degraded due to a member
disk device failure. Replace
the failed disk device; add a
spare to the system to
cause a reconstruct.
Trap overview
Error class
major
informational
critical
informational
minor
major
125

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serverview operations manager v6.12

Table of Contents