Fujitsu ServerView Event Manager User Manual page 135

Serverview operations manager v6.12
Table of Contents

Advertisement

Trap name
tempSensorBroken
tempSensorOk
tempWarn
testTrap
tooManyCabinets
trapAcFail
trapDuplicateCabinetId
trapEventLog
Table 40: ServerControl traps (SC.mib)
ServerView Event Manager
ID
Meaning
630 The temperature sensor is
defective or not connected.
635 The temperature sensor is
working again.
603 The temperature has
reached the warning level.
600 Test trap sent to verify trap
connection.
616 The actual number of
storage subsystems is
higher than the number
stored in the configuration.
632 AC power has failed.
633 Two or more cabinets
(server or storage
subsystems) have the same
ID number.
634 An error was recorded. See
the server management
event / error log (recovery)
for detailed information.
This could have happened
when an error occurred
before the agent was
running or any error without
a specific trap.
Trap overview
Error class
major
informational
major
informational
minor
critical
major
major
135