Troubleshooting Checklist - Enterasys Platinum Distributed Forwarding Engine 7G4205-72 Hardware Installation Manual

Dfe-platinum series
Hide thumbs Also See for Enterasys Platinum Distributed Forwarding Engine 7G4205-72:
Table of Contents

Advertisement

Troubleshooting Checklist

Troubleshooting Checklist
If the module is not working properly, refer to Table
problems, possible causes, and recommended actions to resolve the problem.
Table 4-2 Troubleshooting Checklist
Problem
All LEDs are OFF.
No Local
Management
Password screen.
Cannot navigate
beyond Password
screen.
4-8 Troubleshooting
Possible Cause
Loss of power.
Incorrect terminal setup.
Improper console cable
pinouts.
Corrupt firmware image, or
hardware fault.
Improper username/ password
combination entered.
4‐2 on page 4‐8 for a checklist of 
Recommended Action
Ensure that the DFE module was installed
properly according to the installation
instructions in
Chapter
3, and that the
host chassis is providing power.
Refer to the Enterasys Matrix DFE-
Platinum Series Configuration Guide for
proper setup procedures.
Refer to
Appendix A
for proper COM port
pinouts.
If possible, attempt to download the
image to the DFE module again. Refer to
"Setting the Mode
Switches" on page B-2
for instructions to clear NVRAM.
If the username/password combination
has been forgotten, refer to
Mode
Switches" on page B-2 for
instructions on how to set the mode
switch to reset the username/password
combination to the default values.
"Setting the