Example 4
(Figure
Shows chassis slots 1 through 5 populated with a mix of 6x1xx, 6x2xx, and 6x3xx modules 
and only third generation modules in slots 6 and 7.
In this module arrangement, the 6x3xx module provides a proxy bridge, which enables 
the 6x1xx and 6x2xx modules to communicate with 6x3xx modules in slot 6 or 7. If more 
than one 6x3xx module is installed in slots 1 to 5, the module in the lowest numbered slot 
performs the proxy function for slots 6 and 7. Therefore, if a 6x3xx module is already 
performing the proxy function, and another 6x3xx module is inserted into a lower 
numbered slot, connectivity will be temporarily interrupted, as the new board takes over 
the proxy function. When a 6x3xx module in a lower numbered slot is removed, and there 
is a 6x3xx module in a higher numbered slot, communication is not interrupted.
For Local Management, plugging the Local Management connection into the 6x3xx 
modules will allow management connections to all 6x1xx, 6x2xx, and 6x3xx modules. If 
the Local Management connection is to a 6x1xx or 6x2xx board, only the modules in the 
first five slots will be recognized by the management client.
Rule: There must be at least one 6x3xx module in slots 1 through 5 to enable 
communications between the 6x1xx, 6x2xx, and 6x3xx modules.
Example 5
(Figure
Shows chassis slots 1 and 5 populated with 6x2xx and 6x1xx modules, respectively; slots 2 
through 4 with DFE modules without a bridging module; and slots 6 and 7 with 6x3xx 
modules. 
In this module arrangement, the 6x2xx and 6x1xx modules in slots 1 and 5 can only 
communicate with each other, because there is no 6x3xx module in one of the first five 
slots to serve as the proxy bridge to communicate with the 6x3xx modules in slots 6 and 7. 
The 7x4xxx DFE modules in slots 2, 3, and 4 will operate under one IP address. Since there 
is no DFE bridging module, the DFE modules will not communicate with any other 
modules in the chassis.
Rule: In this example, there must be at least one 6x3xx series module, and a bridging 
module in any of the slots 1 through 5 to enable communications between all generations 
of modules in the chassis.
Example 6
(Figure
The module arrangement in this example is similar to the one shown in Figure
described in Example 5. The only difference is that one of the bridging modules 
(7H4382‐25, 7H4385‐49, 7H4383‐49, or 7H4385‐49) is installed in slot 2, enabling all 
modules to communicate with each other. The 7H4385‐49 is used in this example. 
Rule: In this example, the bridging module serves as both the FTM1‐to‐FTM2 bridge and 
the five‐to‐seven slot proxy bridge. The 6x3xx does not serve as a proxy bridge in this 
configuration because the bridging module is in a slot with a lower number. 
3-1,
D)
3-1, E)
3-1, F)
DFE Module Placement and Installation Rules
DFE-Platinum Series Hardware Installation Guide 3-5
3‐1, E
and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dfe-platinum 7g4285-49Dfe-platinum 7g4205-72

Table of Contents