2.
Plug the RJ45 connector at the other end of the UTP straight‐through cable into the
RJ45‐to‐DB25 modem adapter.
3.
Connect the RJ45‐to‐DB25 adapter to the communications port on the modem.
4.
Turn on the modem.
5.
With a PC connected to a remote modem, you can configure the switch remotely. To
accomplish this, you must configure your PC VT emulation package with the
following parameters.
Parameter
Mode
Transmit
Bits Parity
Stop Bit
6.
When these parameters are set, the Local Management password screen will display.
Refer to the Enterasys Matrix DFE‐Platinum Series Configuration Guide for further
information.
Figure 3-11
Connecting to a Modem
Å
1 UTP straight-through
2 RJ45 COM port
3 RJ45-to-DB25 modem adapter
Ä
Ã
cable with RJ45 connectors
Connecting to COM Port for Local Management
Setting
7 Bit Control
Transmit=9600
8 Bits, No Parity
1 Stop Bit
Â
4 Local modem
5 Remote modem
6 PC
DFE-Platinum Series Hardware Installation Guide 3-21
Á