Last Resort Shutdown Procedure Using OFFLINE/RESET Switch

Caution: This method of shutting down a DFE-Diamond module is not recommended except as a
last resort, because all processes currently running on the module will be interrupted resulting in
loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE-Platinum.
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del módulo en
funcionamiento, lo que podría resultar pérdidas de frames.
To reset a DFE‐Diamond module without it performing an orderly shutdown routine, 
press and hold the OFFLINE/RESET switch for approximately 6 seconds. 
Pulling any DFE‐Diamond module out of the chassis before it has been shut down is not 
recommended. The only safe time to pull a module out of the chassis is after the completion of a 
shutdown and the management LED is flashing amber/off.
Overview of DFE-Diamond Module Shutdown Procedure
Matrix DFE-Platinum Series Module Installation Guide 4-7