Servo Step 8 - Teach Start Sensing Distance
After pressing Teach, you will see a window similar to
the one shown in Figure 4-12.
Place an unwelded part into the fixture. Press both opti-
touch activation switches to jog the horn down to within
0.010 - 0.030 inches above the part. The stroke position
of the thruster will be shown in the Current Position
box. Once you are at the desired position, press Set to
program that distance. Select Exit, and follow instruc-
tions to Home the machine.
iQ Explorer, Teach Start Sensing Distance
Figure 4-12
Servo Step 9 - Select Trigger Method
Still on the Process Settings tab, select Normal as the trigger
method.
iQ Explorer, Select Trigger Method
Figure 4-13
Page 48
Select
Trigger
Method,
Normal
Dukane Manual Part No. 403-575-00