Servo Step 6 - Program Sensing Speed
On the Process Settings tab, find Sensing Speed.
This is the speed (inches per second) at which actua-
tion will move during the approach just before reaching
trigger position. Speed range is from 0.001 to 1.00 in/s
(inches per second). (A typical base start speed is in the
range of 0.20 to 0.40 in/s.)
This feature is exclusive to the servo-controlled systems
and allows for precise, accurate trigger forces.
Servo Step 7 - Program Sensing Start Distance
See Figure 4-11. Sensing Start Distance is the actual
position in the machine travel where motion changes to
Sensing Speed. To program this distance, you must
know how far the horn travels to come in contact with
the top of the part to be welded. If you do not know this
position where this contact is made, select the Teach
button. See Figure 4-12 on the next page.
Dukane Manual Part No. 403-575-00
Sensing Speed
0.20
iQ Explorer, Process Settings > Sensing Speed
Figure 4-11
Section 4 - Operation
Sensing Start Distance