Dukane iQ Series User Manual page 32

Ultrasonic generator/power supply
Hide thumbs Also See for iQ Series:
Table of Contents

Advertisement

iQ Series
Ultrasonic Generator/Power Supply ES User's Manual
Continued from previous page
Pin 17 (Amplitude/Power Regulation Status
(Contact your sales representative about
Output)
Power Regulation availability.)
This status signal is most useful when the power regula-
tion mode is selected. This Out of Regulation status signal
would indicate that due to inadequate pressure against the
ultrasonic horn, the power regulation level setting can
not be achieved when the amplitude level is set to the
maximum level of 100%.
In the amplitude regulation mode, this signal will be
activated at the end of the ramp-up time until the begin-
ning of the ramp-down time. This status signal will be
active for the time the ultrasound is at the programmed
amplitude setting.
Pin 17 is a digital active low status output that activates
when the system is regulating the amplitude or power
level correctly. This output becomes an open circuit when
the system falls out of regulation. When that happens, it
cannot adjust the system output to the output level that
was programmed as the regulation set point.
Pin 18 (Not Used)
Pin 19 (System Power OK Status Output)
Pin 19 is a digital active low status output that activates
when no fault conditions are detected by any of the power
fault detection circuits included in the system. This output
will be an open circuit when any power related fault is
detected in the system.
Pin 20 (Bad Part Status Output)
Pin 20 is a digital active low status output that activates,
either momentarily or until the start of the next welding
cycle, when the welding parameters recorded during the
previous welding cycle are outside of the programmed
bad part limits. This output will be an open circuit when
a bad part has not been detected.
Page 26
Pin 21 (Good Part Status Output)
Pin 21 is a digital active low status output that activates,
either momentarily or until the start of the next welding
cycle, when the welding parameters recorded during the
previous welding cycle do not exceed the programmed
suspect or bad part limits. This output will be an open
circuit after a welding cycle when either a suspect or bad
part has been detected.
Pin 22 (System Ready Status Output)
This status output signal will activate only when the system
is ready to activate ultrasound or begin a weld cycle. Pin
22 is a digital active low status output that activates when
a weld processing cycle is completed and the welding
process control system is ready to start the next welding
cycle. This output will be an open circuit when the welding
process controller determines that the next welding cycle
cannot be started. This includes system faults or off line
active, but not a process fault like Overload.
Pin 23 (Suspect Part Status Output)
Pin 23 is a digital active low status output that activates, ei-
ther momentarily or until the start of the next welding cycle,
when the welding parameters recorded during the previous
welding cycle are outside of the programmed suspect part
limits. This output will be an open circuit after a welding
cycle when a suspect part has not been detected.
Pin 24 (Isolated Common)
Pin 24 is electrically isolated from chassis ground. This
common line should be connected to negative output at a
user-provided isolated 24VDC power supply. The isolated
NPN status output signals can drive PNP inputs.
Pin 25 (Not Used)
Pin 25 is an open connection.
Dukane Manual Part No. 403-575-00

Advertisement

Table of Contents
loading

Table of Contents