Troubleshooting

Troubleshooting

Related messages

When the unit's power is on, messages such as those shown below may be
displayed. When any such message is displayed on the screen, please follow the
instructions described below. If the same message is displayed after the remedy,
or if a message other than the following appears, please contact your dealer or
service company.
Although these messages will automatically disappear after several minutes, they
will be displayed again when the power is turned on.
Message
There is no input signal.
Please confi rm the signal input connection, and the status of the signal source.
The horizontal or vertical frequency of the input signal is not
within the specifi ed range.
Please confi rm the specs for your projector or the signal source specs.
An improper signal is input.
Please confi rm the specs for your projector or the signal source specs.
The internal temperature is rising too much.
Turn the projector off (
minutes or more. After cooling, perform the following check.
- Are there any obstacles to ventilation around the projector?
- Does the temperature around the projector exceed the limit
77)
specifi ed? (
When this message is displayed without the obstacles mentioned
above, replacement of the fi lter unit is required. Replace the fi lter
unit soon according to the procedure directed in the paragraph
"Filter unit" in the chapter "Maintenance" (
resetting the FILTER TIME is needed soon after replacement of
the fi lter unit.
Replacement of the fi lter unit is required.
The value of the timer of the FILTER TIME reached the preset
value of the FILTER MESSAGE on the SERVICE menu under the
OPTION menu (
the procedure directed in the paragraph "Filter unit" in the chapter
"Maintenance" (
needed soon after replacement of the fi lter unit.
The button operation is not available with following
condition.
- While the lens is moving, button operation from the control panel
or the remote control might be ignored. Wait for the LENS SHIFT
indicator stopping blinking.
- Pressing the one of buttons to call a signal input might be ignored,
when all the input ports belonging to the category the button's
name shows are set to the "SKIP" by the item SOURCE SKIP of
the OPTION menu.
Description
20) soon, and allow it to cool down for 20
50). Replace the fi lter unit soon according to
69). Remember resetting the FILTER TIME is
Troubleshooting
69). Remember
71