Timeout On The Mtc Drives - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Explanation of console messages

9.3.2 Timeout on the MTC drives

SXSB007
adsl1 (sadm<n>): timeout on target <t> lun <l> CDB ....
ALERT
or
SXSB007
adsl2 (sadm<n+1>): timeout on target <t> lun <l> CDB ....
ALERT
followed by
WARNING: (adsl,3rd) Adaptec AIC-7870 PCI SCSI HBA: CH0 TARGET<t> LUN<l> is being
reset
Ph_NonInit: calling Ph_AbortDev
Ph_AbortDev: scanning for target <t>
Ph_AbortDev: calling Ph_ScbAbort
adsl2: Ph_ScbAbort scb_ptr->SP_MgrStat 00000040
OptimaAbort
found
abort active
ready to send
done
AbortOptima -> 00000001
complete: 00000000 00000004
SXSE006
mbk<n>t<t>: cmd 1B failed; status -2
ALERT
or other messages with a negative MTC status such as
SXSE006
mbk<n>t<t>: cmd 1B failed; status -<x>
ALERT
Meaning
This message sequence indicates a timeout at the MTC drives.
Response
Notify maintenance staff.