Explanation of console messages
SXSM010
sma#: Memory Module <Id> disabled
ALERT
SXSM010
sma#: Memory Module disabled; Module# = <Id>
ALERT
Meaning
Memory module <Id> is in the "disabled" state. This can be caused by the following:
a) The memory module was disabled in the BIOS setup.
b) The memory module was enabled in the BIOS setup, but has been disabled because
of too many memory errors.
Response
Notify maintenance staff.
SXSM011
sma#: Correctable Memory Error occurred; Module# = <Id>
ALERT
Meaning
A correctable memory error has occurred in memory module <Id>.
Response
Notify maintenance staff.
SXSM012
sma#: Uncorrectable Memory Error occurred; Module# = <Id>
ALERT
Meaning
An uncorrectable memory error has occurred in memory module <Id>.
Response
Notify maintenance staff.
SXSM016
sma#: Fan <Id>: Fan failed
ALERT
Meaning
Non-redundant fan <Id> has failed and must be replaced.
If the fan is inoperable for more than 3 minutes, the SINIX system is shut down and the
server deactivated to prevent the server from overheating.
Response
Notify maintenance staff.
SXSM017
sma#: Fan <Id>: Redundant fan failed
ALERT
Meaning
Redundant fan <Id> has failed. As this fan is redundant, the SINIX system is not shut down.
Response
Notify maintenance staff.