Explanation of console messages
SXVW068
VLPWATCH: ALERT: VW(#068) AutoVLP-Failover: internal or external LAN connection
is not configured!
Meaning
The internal or external LAN connection is broken. The function cannot work properly.
Response
Check the LAN connection and make sure it works correctly.
SXVW069
VLPWATCH: ALERT: VW(#069) -Failover: shutdown, because an error occurred!
Meaning
As a consequence of previous messages the is system shut down (power off).
Response
Reboot the ISP. If the problems that caused the shutdown are still present they must be
analyzed and fixed.
SXVW070
VLPWATCH: ALERT: VW(#070) AutoVLP-Failover: communication sector could not be
determined!
Meaning
The function's communication sectors have been destroyed.
Response
The function must be deconfigured and, once this has been done, configured again. If
problems should occur when the configuration is changed, the function must be stopped
and the maintenance staff must delete the communication sectors manually.
SXVW071
VLPWATCH: ALERT: VW(#071) AutoVLP-Failover: LAN0 is down - switch not useful
Meaning
The SVLP_to_VLP switch is necessary, but it is not executed on account of a defective in-
ternal LAN connection on the SVLP.
Response
Repair the internal LAN connection on the SVLP, check and activate the failed VLP.
SXVW072
VLPWATCH: ALERT: VW(#072) AutoVLP-Failover: LAN1 is down - switch not useful
Meaning
The SVLP_to_VLP switch is necessary, but it is not executed on account of a defective ex-
ternal LAN connection on the SVLP.
Response
Repair the external LAN connection on the SVLP, check and activate the failed VLP.