Fujitsu Siemens Computers pmn User Manual page 474

Centricstor v3.1d user guide
Table of Contents

Advertisement

Message lines
ERR_PDS_01_VSN_NOT_VALID
Meaning
VSN in the tape header and the transferred VSN are not identical. The operation can
therefore not be performed.
Response
This is probably due to manual intervention. If you are sure that there is no user data on the
cartridge, write the correct header.
ERR_PDS_01_GROUP_NOT_VALID
Meaning
PV group in the tape header and the transferred PV group are not identical. The operation
can therefore not be performed.
Response
This is probably due to manual intervention. If you are sure that there is no user data on the
cartridge, write the correct header.
ERR_PDS_01_TAPE_NOT_INIT
Meaning
No tape has yet been initialized and activated. Therefore, the operation cannot be
performed. It is possible that no physical volumes have so far been declared in CentricStor
or that they have not yet been fully initialized.
Response
Notify maintenance staff.
SXPL019
PLM(#19): NOTICE: job cancelled on PDS <PDS-name>, PV <PV-name>, LV<LV-name>
Meaning
A job for the logical volume <LV-name> was aborted due to a timeout.
Response
Notify maintenance staff.
SXPL020
PLM(#20): NOTICE: Reorganisation failed for LV <LV-name> on PV <PV-name>, trying
another PV
Meaning
Reorganization was aborted for this physical volume, the process will be continued with
a different physical volume.
Response
Check whether the physical volume is accessible and can be read.