Fujitsu Siemens Computers pmn User Manual page 610

Centricstor v3.1d user guide
Table of Contents

Advertisement

Glossary
Distribute and Activate ➟
Distributed Tape Volume File System ➟
DNA
The Distribute and Activate (DNA) function must be invoked in
change is made to the configuration of the CentricStor system. This ensures that the
new configuration is distributed to and activated on all the ISPs.
section "Distribute and Activate" on page 188
DTVFS
DTVFS (Distributed Tape Volume File System) is a file system implementation which
was developed specially for CentricStor which has been adapted to the requirements of
high concurrence and of high-speed data traffic both between the
Cache) and hosts and between the
File Systems (TFSs) of the
Emulation
An emulation is a functional simulation of one system by another. The emulated system
receives the same data, executes the same programs and achieves the same results
as the original system.
Example: A logical drive (LD) emulates a physical drive (PD).
Extented Tape Control Center➟
Failover ➟
FC
Fibre Channel (FC) is a standard which was designed for serial and continuous high-
speed transfer of large volumes of data. It is also used in the Storage Area Network (SAN)
within CentricStor and in some cases for the connections between the ICPs and the
hosts and between the IDPs and the back-end devices. The FC controllers used in
CentricStor support bandwidths of between 1 Gb/s (Gigabit per second) and 4 Gb/s.
In the case of a Fibre Channel, each device has a WWNN (World Wide Node Name)
and each port of a device a WWPN (World Wide Port Name) as a unique worldwide
identifier. Each of these is a 64-bit address which is generally presented in hexadecimal
format as 8 bytes separated by colons.
A distinction is made between three types of Fibre Channel topologies :
610
AutoVLP failover function
Switched Fabric (FC-SW)
In the case of the Fibre Channel Switched Fabric, point-to-point connections are
switched between the channel via one or more FC switches.
Arbitrated Loop ( FC-AL)
In the case of the Fibre Channel Arbitrated Loop a logical bus is involved on which all
terminals share the same bandwidth. In CentricStor, FC-AL can only be used to
connect back-end devices.
Point-to-Point (FC-P2P)
This refers to a direct connection between two terminals.
DNA
DTVFS
TVC
and tape drives. In CentricStor V3.1D, all Tape
TVC
are of the type dtvfs.
XTCC
GXCC
every time a
TVC
(Tape Volume
U41117-J-Z125-7-76

Advertisement

Table of Contents
loading

This manual is also suitable for:

Centricstor v3.1d

Table of Contents