Message lines
SXRD104
WARNING: raid 0:1:0 - Disk: Write-Only, 17300 MB
Meaning
A rebuild is active for the physical disk of controller 0, channel 1, target ID 0.
9.2.15.2

FibreCAT S80 messages

SXRD00<n>
s80d: RAID: <weight>: <raid-id> Raid<raid#> enclosure <shelf#> <component>
<status>
Meaning
If there is a status change in a S80 component, a message will be output on the console.
The terms used here have the following meanings:
n
weight
raid-id
raid#
shelf#
component
status
488
1 - 8
Error severity:
NOTICE
WARNING
ERROR
ALERT
FibreCAT identification (target# of the 2 RAID controllers)
Number of the RAID system (1 – 8)
Number of the shelf (1 – 7)
Internal component of the shelf
Disk drive (1 – 14)
Power supply (1 – 2)
Cooling fan (1 – 4)
Enclosure services module (1 – 2)
Loop monitor
Voltage sensor (1 – 6)
Current sensor (1 – 6)
Temperature sensor (1 – 4)
Status of the component
OK
Warning
Critical
Not Installed
Not Available
Unknown
Explanation of console messages
information
soft error
error
critical error
Error corrected
Non-critical error (sensor only)
Critical error
Component removed or faulty
Component not in operation
Status not available (sensor only)