Sxvd - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Message lines
SXTF011
DTV_FSCK(dev=<maj,min>): <message> ...<message>
Meaning
Normal output of the implicit file system check carried out when mounting a DTV file
system.
9.2.24 SXVD... (Distributed Tape Volume Driver)

SXVD001

vdrv<n> (FAILOVER): switch ...
ERROR
See the
RAID system" on page
SXVD002
vdrv<n> (FAILOVER): Error exit 0130002A E54EC000
See the
SXVD003
vdrv<n> (MULTIPATH): switch 0:<n-2>->1:<n-1>
SXVD003
vdrv<n> (MULTIPATH): switch 1:<n-1>->0:<n-2>
Meaning
The path between the PC and the FC switch was switched over to a redundant (fallback)
path. This was due to disruption of the connection between the PC and the FC switch
caused, for example, by a controller failure (in the PC), GBIC failure, cabling problems, or
incorrectly identified topology.
Response
Notify maintenance staff.
SXVD004
vdrv<n> (FAILOVER): int switching
See the
516
section "Failure of RAID systems" on page 540
541.
section "Failure of RAID systems" on page
section "Failover at the RAID system" on page 541
Explanation of console messages
and the
section "Failover at the
540.
U41117-J-Z125-7-76