Cartridge drives (real)
If Service Information Messages (SIM) or Medium Information Messages (MIM) are present
in the drive, these are indicated by means of a yellow or red flashing SIM/MIM symbol,
depending on their severity (severity 0/1/2/3 = Service/Moderate/Serious/Acute). If the
device hangs, the entire block is marked with a large red "X". Devices which are recognized
by XTCC as SCSI targets on the SCSI bus but which cannot be identified further are
assigned the type designation "xxxx". In this case, the device type is depicted by means of
a question mark.
The following information is displayed:
Vendor ID, Product ID
Firmware Revision
Drive Serial Number
Drive Status
SIM/MIM Severity
Check Condition
Medium Type
Password
Compression Mode
Controller, Target, Logical Unit
Switch: Local Domain x, Port y
424
Appears only if SIMs or MIMs are present, and indicates
the severity of the message.
Appears only in the event of errors.
Appears only if the device is loaded.
Password of device, not used in CentricStor.
Data compression activated/deactivated.
SCSI topology
This information is displayed for archives with the target
numbers 128...2047. The local domain is in the value
range 1...8. In the case of FC switches with more than
16 ports, it can differ from the "Domain" displayed in
GXCC as follows:
GXCC Domain
XTCC Local Domain = 1 2 ... 7 8 1 2 3 etc.
= 1 2 ... 7 8 9 10 11 etc.
U41117-J-Z125-7-76
XTCC