Mode switch
Communication between the recorder and a system device using PS·Data can be performed by RS 485 interface. Devices on
both ends of the RS485 connection are necessary to be terminated.
The mode switch setting differs depending on whether to use the recorder as a receiver or a system controller.
When connecting RS485 cameras to the recorder, devices on both ends of the connection are necessary to be terminated.
• When the recorder is on the end of the connection with a sys-
tem controller
PS·Data termination switch 1: On
• When the recorder is on the end of the connection with a
device controller
PS·Data termination switch 2: On
• When connecting RS485 cameras
Set the termination switch of the RS485 port to which the
RS485 camera is connected
Connect to the RS485 port 1: Set the termination switch of
the RS485 port (1) to "On".
Connect to the RS485 port 2: Set the termination switch of
the RS485 port (2) to "On".
• When connecting in 2-wire connection
Connect to the RS485 port 1:
Connect to the RS485 port 2:
• When connecting in 4-wire connection
Connect to the RS485 port 1:
Connect to the RS485 port 2:

RS485 port

Inside block diagram
TA
TB
DATA
RA
RB
GND
GND
RB
RA
TA
TB
IN
OUT
Set no. 2 and no. 3 to "On".
Set no. 5 and no. 6 to "On".
Set no. 2 and no. 3 to "Off".
Set no. 5 and no. 6 to "Off".
RS485 (1) Termination switch
RS485 (1) 2-wire/4-wire
connection switch
RS485 (2) Termination switch
RS485 (2) 2-wire/4-wire
connection switch
PS·Data termination switch 1
PS·Data termination switch 2
ON
1 2 3 4 5
6 7 8
51