Table 5. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet
controller (continued)
Error code
Description
(hex)
0x02
Explanation: Bad node address (multicast address). Action: Make sure the
locally administered address is valid, if one is specified. The address can
not be a multicast address.
0x03
Explanation: Failed self-test. Action: Make sure a cable is attached to the
Ethernet connector. If the problem persists, call for service.
0x0D
Explanation: Could not allocate enough memory for transmit queues.
Action:
1. From the Windows NT desktop, select Start -> Control Panel ->
Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the resource values that apply to the transmit queue.
0x0E
Explanation: Could not allocate enough memory for receive queue. Action:
1. From the Windows NT desktop, select Start -> Control Panel ->
Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the resource values that apply to the receive queue.
0x0F
Explanation: Could not allocate enough memory for other structures.
Action:
1. From the Windows NT desktop, select Start -> Control Panel ->
Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the value for the resource named in the message.
0x10
Explanation: Did not find any Ethernet controllers. Action: Using the
Configuration/Setup Utility, make sure that Ethernet is enabled.
0x11
Explanation: Multiple Ethernet controllers found, but none matched the
required ID. Action: Using the Configuration/Setup Utility, make sure that
Ethernet is enabled.
0x13
Explanation: Did not find any Ethernet controllers that matched the
required subven/subdev. Action: Using the Configuration/Setup Utility,
make sure that Ethernet is enabled.
0x16
Explanation: Single adapter found but multiple instances tried to load.
Action: Using the Configuration/Setup Utility, make sure that Ethernet is
enabled, and that the slot containing the IBM 10/100 Ethernet Adapter or
the IBM 10/100 EtherJet
0x17
Explanation: Slot parameter not specified in the registry. Action: Remove
the adapter driver and reinstall it. If the problem persists, call for service.
All other
Action: Call for service.
4-character
hexadecimal
codes
PCI adapter is enabled.
25
Diagnostics