Error Code/Symptom
1800 (No more hardware
interrupt available for PCI
adapter)
1962 (Drive does not contain
a valid boot sector)
2400 (Video controller test
failure)
2462 (Video memory
configuration error)
5962 (IDE CD-ROM
configuration error)
8603 (Pointing Device Error)
00012000 (Processor machine
check)
00019501 (Microprocessor 1 is
not functioning - check VRM
and processor LEDs)
00019502 (Microprocessor 2 is
not functioning - check VRM
and processor LEDs)
00019701 (Microprocessor 1
failed BIST)
00019702 (Microprocessor 2
failed BIST)
00180100 (No room for PCI
option ROM)
00180200 (No more I/O space
available for PCI adapter)
FRU/Action
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Verify a bootable operating system is installed.
2. If RAID system, refer to the Hardware Maintenance Manual for the specific
RAID adapter.
3. Run Diagnostics
4. Hard Disk Drive
5. Cable
6. SCSI Backplane
7. System Board
1. Video Adapter (if installed)
2. System Board
1. Video Adapter (if installed)
2. System Board
1. Run Configuration/Setup
2. CD-ROM Drive
3. CD-ROM Power Cable
4. IDE Cable
5. System Board
6. Battery
1. Pointing Device
2. System Board
1. Update BIOS
2. Replace microprocessor
1. Microprocessor 1
2. System Board
1. Microprocessor 2
2. System Board
1. Microprocessor 1
2. System Board
1. Microprocessor 2
2. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board