Error Code/Symptom
062 (Three consecutive boot
failures using the default
configuration.)
101, 102, 106 (System and
microprocessor error)
111 (Channel check error)
114 (Adapter read-only
memory error)
129 (Internal cache error)
151 (Real time clock error)
161 (Real time clock battery
error)
162 (Device Configuration
Error)
Note: Be sure to load the
default settings and any
additional desired settings;
then, save the configura-tion.
163 (Real-Time Clock error)
164 (Memory configuration
changed, see "Memory
Settings" on page 32.)
175 (Hardware error)
176, 177, 178 (Security
hardware error)
184 (Power-on password
corrupted)
185 (Drive startup sequence
information corrupted)
186 (Security hardware
control logic failed)
187 (VPD serial number not
set.)
FRU/Action
1. Run Configuration/Setup
2. Battery
3. System Board
4. Microprocessor
1. System Board
1. Failing adapter
2. DIMM
3. System board
1. Failing adapter
2. Run diagnostics
1. Microprocessor
2. Optional microprocessor (if installed)
1. Run Diagnostics
2. Battery
3. System Board
1. Run Configuration/Setup
2. Battery
3. System Board
1. Run Configuration/Setup
2. Battery
3. Failing Device
4. System Board
1. Run Configuration/Setup
2. Battery
3. System Board
1. Run Configuration/Setup
2. DIMM
3. System Board
1. System Board
1. Run Configuration/Setup
2. System Board
1. Run Configuration/Setup
2. System Board
1. Run Configuration/Setup
2. System Board
1. Run Configuration/Setup
2. System Board
1. Set serial number in Setup
2. System Board
113
Symptom-to-FRU index

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 220 8645

Table of Contents