Configuring The Switch Priority Of A Vlan - Cisco 2950 - Catalyst Switch Configuration Manual

Software configuration guide
Hide thumbs Also See for 2950 - Catalyst Switch:
Table of Contents

Advertisement

Configuring Spanning-Tree Features
To return the interface to its default setting, use the no spanning-tree [vlan vlan-id] cost interface
configuration command. For information on how to configure load sharing on trunk ports by using
spanning-tree path costs, see the

Configuring the Switch Priority of a VLAN

You can configure the switch priority and make it more likely that the switch will be chosen as the root
switch.
Note
Exercise care when using this command. For most situations, we recommend that you use the
spanning-tree vlan vlan-id root primary and the spanning-tree vlan vlan-id root secondary global
configuration commands to modify the switch priority.
Beginning in privileged EXEC mode, follow these steps to configure the switch priority of a VLAN. This
procedure is optional.
Command
Step 1
configure terminal
Step 2
spanning-tree vlan vlan-id priority priority
Step 3
end
Step 4
show spanning-tree vlan vlan-id
Step 5
copy running-config startup-config
To return the switch to its default setting, use the no spanning-tree vlan vlan-id priority global
configuration command.
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
14-20
"Load Sharing Using STP" section on page
Purpose
Enter global configuration mode.
Configure the switch priority of a VLAN.
For vlan-id, you can specify a single VLAN identified by
VLAN ID number, a range of VLANs separated by a
hyphen, or a series of VLANs separated by a comma. The
range is 1 to 1005 when the SI is installed and 1 to 4094
when the EI is installed.
For priority, the range is 0 to 61440 in increments of
4096; the default is 32768. The lower the number, the
more likely the switch will be chosen as the root switch.
Valid priority values are 4096, 8192, 12288, 16384,
20480, 24576, 28672, 32768, 36864, 40960, 45056,
49152, 53248, 57344, and 61440. All other values are
rejected.
Return to privileged EXEC mode.
Verify your entries.
(Optional) Save your entries in the configuration file.
Chapter 14
Configuring STP
17-22.
78-11380-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2955

Table of Contents