Service Manual
FEEDER PWB Board Removal
3.2.3.8
Remove the paper cassette and imaging cartridge.
1.
Remove the feeder assembly. (Refer to Section 3.2.3.1.)
2.
3.
Remove 2 CBB screws (M3 x 8) securing the feeder tie plate, and remove it.
Remove 2 CBB screws (M3 x 8) and 2 CB screws (M3 x 8) securing the feed housing (right),
and remove it.
Remove 2 CB screws (M3 x 8) securing the FEEDER PWB board, and remove it.
5.
Disconnect comectors P/Jl16, P/J201, and P/J202 from the FEEDER PWB board.
6.
Figure 3-21. Removing the FEEDER PWB Board
3.2.3.9 Size Spring Removal
1.
Remove the paper cassette and imaging cartridge.
2.
Remove the feeder assembly. (Refer to Section 3.2.3.1.)
3. Remove 2 CBB screws (M3 x 8) securing the feeder tie plate, and remove it.
4. Remove 2 CBB screws (M3 x 8) and 2 CB screws (M3 x 8) securing the feed housing (right),
and remove it.
5. Remove 1 CB screw (M3 x 8) securing the size spring, and remove it.
Rev. A
Figure 3-22. Removing the Size Spring
Disassembly and Assembly