Port Events (500 through 599)

Event Code: 506
Message:
Fibre Channel port failure.
Severity:
Major.
Explanation:
A Fibre channel port failed. The amber LED corresponding to the port illuminates to indicate the failure. Ports with
LEDs extinguished remain operational.
Action:
Perform a a data collection and return the CD to support personnel. Perform a switch reset. If the problem
persists, replace the switch.
Event Data:
Byte 0 = port number.
Byte 1 = engineering reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = reason code specific.
Byte 16 = connector type.
Distribution:
Product
EFCM Basic
Event Log
Event Code: 507
Message:
Loopback diagnostics port failure.
Severity:
Informational.
Explanation:
A loopback diagnostic test detected a Fibre Channel port failure.
Action:
No action required. An event code 506 is generated if this diagnostic failure results in a hard port failure.
Event Data:
Byte 0 = port number.
Byte 1 = engineering reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution:
Product
EFCM Basic
Event Log
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
Bytes 17 and 18 = transmitter technology.
Byte 19 = distance capability.
Byte 20 = supported transmission media.
Byte 21 and 22 = speed capability.
E-Mail
Call-Home
Sense Info
Bytes 8 - 11 = reason code specific.
Byte 12 = test type.
E-Mail
Call-Home
Sense Info
Event Code Tables
Host
Link Incident
Log
Host
Link Incident
Log
Event Code Tables
A-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 4500

Table of Contents