Figure 4-16

Set Online State

Save Data Collection Dialog Box

2. Remove the backup CD from the management server's compact
disk-rewritable (CD-RW) drive and insert a blank rewritable CD.
3. At the Save Data Collection dialog box, select the compact disc
drive (D:\) from the Look in drop-down menu, type a descriptive
name for the collected maintenance data in the File name field,
then click Save.
4. The Data Collection dialog box displays with a progress bar that
shows percent completion of the data collection process. When
the process reaches 100%, the Cancel button changes to a Close
Button.
5. Click Close to close the dialog box.
6. Remove the CD with the newly-collected maintenance data from
the management server's CD-RW drive. Return the CD with the
failed FRU to support personnel for failure analysis.
7. To ensure the backup application operates normally, replace the
original backup CD in the management server's CD-RW drive.
This section describes procedures to set the product online or offline.
Operational states are:
• Online - When the product is set online, an attached device can
log in if the port is not blocked. Attached devices in the same
zone can communicate with each other.
• Offline - When the product is set offline, all ports are set offline
and operation of attached Fibre Channel devices is disrupted. The
product transmits the OLS to attached devices, and the devices
cannot log in.
Repair Information