CTP Card Events (400 through 499)

Event Code: 400
Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a failed FRU as indicated by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure is indicated, replace the
power supply. Perform a data collection and return the CD and faulty FRU to support personnel.
Event Data:
Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply assembly.
Byte 1 = FRU slot number.
Distribution:
Product
EFCM Basic
Event Log
Event Code: 410
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can occur automatically after a
firmware fault (event code 411), or be user-initiated. Event data indicates the type of reset.
Action:
No action required.
Event Data:
Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution:
Product
EFCM Basic
Event Log
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
E-Mail
Call-Home
Sense Info
E-Mail
Call-Home
Sense Info
Event Code Tables
Host
Link Incident
Log
Host
Link Incident
Log
Event Code Tables
A-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 4500

Table of Contents