Install Or Upgrade Software - McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual

Fw 08.01.00 mcdata sphereon 4500 fabric switch installation and service manual (620-000159-330, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Repair Information
Install or Upgrade
Software
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
4-50
8. Change the switch IP address and restart the management server
session as follows:
a. A grey square with a yellow exclamation mark appears
adjacent to the icon representing the reset switch, indicating
switch is not communicating with the management server.
a. Delete the icon representing the reset switch. At the SAN
management application, select Setup from the Discover menu.
The Discover Setup dialog box displays
b. Select (highlight) the entry representing the reset switch in the
Available Addresses window and click Remove.
c. At the Discover Setup dialog box, click OK. The switch is no
longer defined to the management server.
d. Change the switch IP address through the maintenance port.
Refer to
Task 5: Configure Product Network Information (Optional)
for instructions.
e. Identify the switch to the SAN management application. Refer
to
Task 13: Configure the Product to the Management Application
for instructions.
The delivered SAN management application is provided on the EFC
Management Applications CD-ROM. Subsequent software versions for
upgrade are provided to customers through the McDATA Filecenter.
NOTE: When upgrading software, follow all procedural information
contained in release notes or EC instructions that accompany the version.
Such information supplements information provided in this general
procedure.
To install or upgrade the SAN management application:
1. At the management server, close and exit all applications, then
perform one of the following:
— Insert the EFC Management Applications CD-ROM into the
CD-ROM drive of the server.
— Ensure the desired software version is obtained from the
Filecenter and resident on the server hard drive. Refer to
Download Firmware or Software from the Filecenter
instructions.
(Figure
4-21).