Power Supply Events (200 through 299)

Event Code: 200
Message:
Power supply AC voltage failure.
Severity:
Major.
Explanation:
AC input to the power supply is disconnected or AC circuitry in the power supply failed. The event only occurs
when two power supplies are installed. The second power supply assumes the full operating load.
Action:
Ensure the power supply is connected to facility AC power and verify operation of the facility power source. If the
AC voltage does not recover (indicated by event code 203), replace the failed power supply. Perform a data
collection and return the CD and failed power supply to support personnel.
Event Data:
No supplementary data included.
Distribution:
Product
EFCM Basic
Event Log
Event Code: 201
Message:
Power supply DC voltage failure.
Severity:
Major.
Explanation:
DC circuitry in the power supply failed. The event only occurs when two power supplies are installed. The second
power supply assumes the full operating load.
Action:
Replace the failed power supply. Perform a data collection and return the CD and failed power supply to support
personnel.
Event Data:
No supplementary data included.
Distribution:
Product
EFCM Basic
Event Log
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
E-Mail
Call-Home
Sense Info
E-Mail
Call-Home
Sense Info
Event Code Tables
Host
Link Incident
Log
Host
Link Incident
Log
Event Code Tables
A-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 4500

Table of Contents