Rack-Mount Installation; Mounting Bracket Installation (Ethernet Hub) - McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual

Fw 08.01.00 mcdata sphereon 4500 fabric switch installation and service manual (620-000159-330, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Rack-Mount
Installation
Figure 2-2
5. Connect the AC power strip to facility power. Power for each hub
switches on when the strip is connected to facility AC power.
6. Inspect the front panel of each hub. Ensure each green Power
light-emitting diode (LED) illuminates.
Perform the following steps to install and configure up to three
Ethernet hubs in a Fabricenter cabinet or customer-supplied 19-inch
equipment rack. A pointed instrument (pencil tip or bent paper clip),
#2 Phillips screwdriver, and 1/8-inch Allen wrench are required.
1. Secure one mounting bracket to each side of the first hub as
shown in
Figure
2-2. Use the two brackets and four pan-head
Phillips screws (8/32 x 0.5-inch) provided.

Mounting Bracket Installation (Ethernet Hub)

2. Position the hub as directed by the customer. Align screw holes in
the mounting brackets with screw holes in the rack-mount
standards.
3. Secure both sides of the hub to the rack-mount standards. Use the
1/8-inch Allen wrench and four Allen-head mounting screws
(10/32 x 0.5-inch) provided.
4. Repeat
step 1
through
5. To daisy-chain (connect) the hubs:
a. To connect the top and middle stacked hubs, connect an RJ-45
patch cable to port 24 of the top hub, then connect the cable to
port 12 of the middle hub.
step 3
for the remaining hubs.
Installation Tasks
Installation Tasks
2-7
2